Detex V40EEFC362899 36" Delayed Egress Rim Exit Device
Detex$1,821.00
$3,103.00
-41%Typically ships in 3-5 business days.
Volume pricing on 10+ units.
US Made Products
Flat Rate Shipping
Business Support
American businesses trust US Made Supply because we do the research.
Call 714-248-6555 or email us.
The Detex V40 EE is a Grade 1 rim exit device with delayed egress built in. Push the bar and the device holds the door locked for 15 seconds while a 100 decibel alarm sounds, which gives staff time to respond before the door releases. It is the configuration specified for stockrooms, back-of-house exits, behavioral health units and retail secondary exits, where an unmonitored exit is a loss or safety problem. This is the 36 in device in satin aluminum or black. Detex describes its products as assembled in America.
Specifications
| Model | V40 EE FC3 628 99 36 (711 for black), plus the option codes selected above |
| Device type | Wide stile rim exit device |
| Door width | Fits a 36 in (3 ft) wide door |
| Delay | 15 second delayed egress, 100 dB alarm |
| Dogging | Cylinder dogging (CD) or no dogging (Detex code LD), selected above. Mortise cylinder not included |
| Power supply | Filtered and regulated 24VDC Detex supply, included except on the without-power-supply build (Detex code PS0). Detex does not name the model in its EE package descriptions |
| Conduit kit | Flexible 3 ft conduit kit (FC3), included on every build in this ladder |
| Alarm backup | 9V battery, alarm function only, during power loss |
| Latchbolt | Stainless steel 3/4 in deadlocking Pullman type |
| Strike | 99 surface strike |
| Finish | 628 satin aluminum clear anodized, or 711 black anodized aluminum (black comes with cylinder dogging and the power supply) |
| Base material | Aluminum rail, stainless steel latchbolt |
| Listings | UL 305 panic hardware; ANSI/BHMA A156.3 Grade 1 |
How the delay works
The alarm is triggered by latchbolt movement, so the device reacts to someone actually pushing the bar rather than to a door position switch. A fire alarm input wires in at the power supply, which is how the door is released on an alarm condition. Detex rates the housing as tamper resistant and the 9V battery maintains the alarm, but not the delay, if power is lost.
Where a delayed egress device is permitted, and for how long the delay may run, is set by the adopted building and life safety codes for your occupancy. Start with NFPA 101 and IBC Chapter 10, and confirm with your authority having jurisdiction before specifying.
Choosing the power supply option
The device runs on filtered and regulated 24VDC and cannot operate without a supply. The standard build ships with a Detex supply, which is what a single opening needs. Detex does not name the model in its EE package descriptions, and its current price list introduces the PS80 as replacing the 90-800 while still listing the older model, so confirm which one you receive if battery backup matters: a 90-800 has no battery-charging circuit, while a PS80 can carry batteries.
The without-power-supply build is not a way to save money on a single door. Detex calls it PS0, and it exists for the second leaf of a pair, where the two devices share the supply that came with the first. A Detex filtered and regulated 24VDC supply is still required. If this is a single opening, or you are not certain a Detex supply with spare capacity is already at the door, choose the build that includes it.
Choosing the dogging option
Cylinder dogging holds the latch retracted so the door pushes open freely during open hours. The mortise cylinder is not included, so order one with the device or the unit arrives unable to dog. If the opening should stay latched at all times, the no-dogging build (Detex code LD) is the same price.
Related hardware and standards
Panic hardware requirements and mounting heights: IBC panic hardware. Grade 1 testing basis: ANSI/BHMA A156.3. The panic hardware standard itself: UL 305.
Documents and downloads
Detex Delayed Egress (EE) product page · Detex V40 series page
Weatherseal parts sized for a 36 in door
The Detex V40 EE is a Grade 1 rim exit device with delayed egress built in. Push the bar and the device holds the door locked for 15 seconds while a 100 decibel alarm sounds, which gives staff time to respond before the door releases. It is the configuration specified for stockrooms, back-of-house exits, behavioral health units and retail secondary exits, where an unmonitored exit is a loss or safety problem. This is the 36 in device in satin aluminum or black. Detex describes its products as assembled in America.
Specifications
| Model | V40 EE FC3 628 99 36 (711 for black), plus the option codes selected above |
| Device type | Wide stile rim exit device |
| Door width | Fits a 36 in (3 ft) wide door |
| Delay | 15 second delayed egress, 100 dB alarm |
| Dogging | Cylinder dogging (CD) or no dogging (Detex code LD), selected above. Mortise cylinder not included |
| Power supply | Filtered and regulated 24VDC Detex supply, included except on the without-power-supply build (Detex code PS0). Detex does not name the model in its EE package descriptions |
| Conduit kit | Flexible 3 ft conduit kit (FC3), included on every build in this ladder |
| Alarm backup | 9V battery, alarm function only, during power loss |
| Latchbolt | Stainless steel 3/4 in deadlocking Pullman type |
| Strike | 99 surface strike |
| Finish | 628 satin aluminum clear anodized, or 711 black anodized aluminum (black comes with cylinder dogging and the power supply) |
| Base material | Aluminum rail, stainless steel latchbolt |
| Listings | UL 305 panic hardware; ANSI/BHMA A156.3 Grade 1 |
How the delay works
The alarm is triggered by latchbolt movement, so the device reacts to someone actually pushing the bar rather than to a door position switch. A fire alarm input wires in at the power supply, which is how the door is released on an alarm condition. Detex rates the housing as tamper resistant and the 9V battery maintains the alarm, but not the delay, if power is lost.
Where a delayed egress device is permitted, and for how long the delay may run, is set by the adopted building and life safety codes for your occupancy. Start with NFPA 101 and IBC Chapter 10, and confirm with your authority having jurisdiction before specifying.
Choosing the power supply option
The device runs on filtered and regulated 24VDC and cannot operate without a supply. The standard build ships with a Detex supply, which is what a single opening needs. Detex does not name the model in its EE package descriptions, and its current price list introduces the PS80 as replacing the 90-800 while still listing the older model, so confirm which one you receive if battery backup matters: a 90-800 has no battery-charging circuit, while a PS80 can carry batteries.
The without-power-supply build is not a way to save money on a single door. Detex calls it PS0, and it exists for the second leaf of a pair, where the two devices share the supply that came with the first. A Detex filtered and regulated 24VDC supply is still required. If this is a single opening, or you are not certain a Detex supply with spare capacity is already at the door, choose the build that includes it.
Choosing the dogging option
Cylinder dogging holds the latch retracted so the door pushes open freely during open hours. The mortise cylinder is not included, so order one with the device or the unit arrives unable to dog. If the opening should stay latched at all times, the no-dogging build (Detex code LD) is the same price.
Related hardware and standards
Panic hardware requirements and mounting heights: IBC panic hardware. Grade 1 testing basis: ANSI/BHMA A156.3. The panic hardware standard itself: UL 305.
Documents and downloads
Detex Delayed Egress (EE) product page · Detex V40 series page
Frequently Asked Questions
Does the 15 second delay meet code for my building?
That depends on your occupancy and the code edition your jurisdiction has adopted. Delayed egress locking is addressed in NFPA 101 and in IBC Chapter 10, and both set conditions on where it is permitted, the delay duration, signage, and release on fire alarm or power loss. The device provides a 15 second delay; whether that is permitted on your opening is a determination for your AHJ and the engineer of record.
Is the power supply included?
On the standard build, yes. It ships with the filtered and regulated 24VDC Detex supply the device requires. Detex does not name the model in its EE package descriptions and is replacing the 90-800 with the PS80, which matters if you are relying on battery backup, because a 90-800 has no battery-charging circuit. The without-power-supply build (Detex code PS0) omits it, and it is intended for the second leaf of a pair sharing the supply from the first device, not as a cheaper option for a single door. A Detex supply is required either way.
What is FC3?
FC3 is the flexible 3 ft conduit kit that carries the wiring off the device. It is included on every build in this ladder, so it is not something you choose between. It is not the power supply, which is a separate Detex 24VDC unit.
Is the mortise cylinder included for cylinder dogging?
No. Cylinder dogging builds ship without a cylinder, so order one alongside the device or it will arrive unable to dog. If you do not need dogging, the no-dogging build is the same price.
What happens in a power failure?
A 9V battery maintains the alarm function only. The 15 second delay is not maintained on battery. A fire alarm input wires in at the power supply for release on an alarm condition.
Will this work on a fire rated door?
No. This 36 in device is listed to UL 305 as panic hardware. Fire exit hardware is a separate Detex model with an F prefix in the part number: we carry the FV40 rim and FV50 vertical rod fire exit devices, and Detex also builds a fire rated delayed egress version, less dogging only, which we can quote. Do not install panic hardware on a labeled fire door assembly.
More from Detex
View all →
Manufacturer: Detex
Detex 01P628 Blank Plate Exit Device Trim Satin Aluminum
$100.00

Manufacturer: Detex
Detex 01P711 Blank Plate Exit Device Trim Black Anodized
$100.00

Manufacturer: Detex
Detex 02A 689 Straight Pull Exit Device Trim Aluminum Painted
$100.00

Manufacturer: Detex
Detex 02A693 Straight Pull Exit Device Trim Black Painted
$100.00

Manufacturer: Detex
Detex 02AN693 Narrow Straight Pull Exit Device Trim Black Painted
$100.00

Manufacturer: Detex
Detex 03A689 Straight Pull Exit Device Trim Aluminum Painted
$100.00

Manufacturer: Detex
Detex 03A693 Straight Pull Exit Device Trim Black Painted
$100.00

Manufacturer: Detex
Detex 03AN689 Narrow Straight Pull Exit Device Trim Aluminum Painted
$100.00