Need help? Call or text 714-248-6555

Rated 4.9/5 by verified buyers

US Made Supply
/
Type at least 2 characters, then press Enter to see all results.
Roofing & Roofs
Flat or Low Slope
Architectural

NGP drawing of the 9990 at the top of a fire door: a stainless flat plate on the pull side and an L shaped intumescent cap on the push side, for a head gap of up to 1/2 in
NGP drawings of the 9990 installed at the door head, with and without its stainless end caps

NGP GapGuard 9990 Fire Door Top Gap Solution Stainless Steel

NGP

$406.00

Typically ships in 1-3 business days.

Volume pricing on 10+ units.

Length

Secure Checkout

We usually reply the same business day

US Made Products

Flat Rate Shipping

Business Support

American businesses trust US Made Supply because we do the research.

Call 714-248-6555 or email us.

The NGP GapGuard 9990 closes an excessive gap at the top of a fire door, between the door and the frame head. NGP states it is UL certified for head clearances over 1/8 in, up to 1/2 in, on wood or hollow metal fire doors rated up to 180 minutes, and recommends it for doors with parallel arm closers. It mounts on the door, not the frame. See all our door seals and gasketing.

Specifications

Model NGP 9990, #304 brushed stainless steel. Length selected above
Gap it fixes Head clearance over 1/8 in, up to 1/2 in
Fire rating Wood or hollow metal fire doors up to 180 minutes, per NGP
What is in it Stainless steel flat plate (pull side), stainless steel L shaped intumescent cap (push side), stainless steel end caps and #6 x 3/4 in stainless screws
Handing Non-handed
Lengths 36 and 48 in, cut to fit

Fire rated doors

NGP states the 9990 is certified by UL to ANSI/UL 10C (positive pressure) and to ANSI/UL 10B and CAN/ULC-S104, for use in the US and Canada, and that it complies with IBC, NFPA 80 and NFPA 252 for hollow metal and wood fire doors. NGP calls it a positive pressure tested miscellaneous fire door accessory.

The door's label and listing, NGP's installation instructions and your authority having jurisdiction decide whether a repair is accepted. Measure the gap between door and frame on the pull side of the door, where an NFPA 80 inspection checks it. See our NFPA 80 page for the clearance limits.

Installing

NGP's instructions: cut both parts to fit, prepare for any top latching hardware following that hardware's instructions, and keep clear of the door's fire label. Close the door and set the intumescent cap on the push side with 1/8 in clearance to the frame head, then fit the flat plate on the pull side, aligned with the top of the cap. Fit the end caps if you want a finished look.

Documents

NGP 9990 installation instructions
NGP 9990 cut sheet
NGP 9990 product page
NGP GapGuard catalog

The NGP GapGuard 9990 closes an excessive gap at the top of a fire door, between the door and the frame head. NGP states it is UL certified for head clearances over 1/8 in, up to 1/2 in, on wood or hollow metal fire doors rated up to 180 minutes, and recommends it for doors with parallel arm closers. It mounts on the door, not the frame. See all our door seals and gasketing.

Specifications

Model NGP 9990, #304 brushed stainless steel. Length selected above
Gap it fixes Head clearance over 1/8 in, up to 1/2 in
Fire rating Wood or hollow metal fire doors up to 180 minutes, per NGP
What is in it Stainless steel flat plate (pull side), stainless steel L shaped intumescent cap (push side), stainless steel end caps and #6 x 3/4 in stainless screws
Handing Non-handed
Lengths 36 and 48 in, cut to fit

Fire rated doors

NGP states the 9990 is certified by UL to ANSI/UL 10C (positive pressure) and to ANSI/UL 10B and CAN/ULC-S104, for use in the US and Canada, and that it complies with IBC, NFPA 80 and NFPA 252 for hollow metal and wood fire doors. NGP calls it a positive pressure tested miscellaneous fire door accessory.

The door's label and listing, NGP's installation instructions and your authority having jurisdiction decide whether a repair is accepted. Measure the gap between door and frame on the pull side of the door, where an NFPA 80 inspection checks it. See our NFPA 80 page for the clearance limits.

Installing

NGP's instructions: cut both parts to fit, prepare for any top latching hardware following that hardware's instructions, and keep clear of the door's fire label. Close the door and set the intumescent cap on the push side with 1/8 in clearance to the frame head, then fit the flat plate on the pull side, aligned with the top of the cap. Fit the end caps if you want a finished look.

Documents

NGP 9990 installation instructions
NGP 9990 cut sheet
NGP 9990 product page
NGP GapGuard catalog

More from NGP

View all →
NGP GapGuard GAP90 components: a gray steel stop extender with a UL mark, a gray intumescent seal and a charcoal silicone smoke seal

Manufacturer: NGP

NGP GapGuard GAP90 Fire Door Head and Jamb Gap Solution

$521.00

NGP drawing of the GAP90-ME formed metal edge screwed to the edge of a wood door, with its anchoring bores filled with fire caulk

Manufacturer: NGP

NGP GapGuard GAP90-ME Fire Door Meeting Edge and Perimeter Gap Solution

$521.00

NGP drawing of the 9590 installed at the bottom of a fire door: a stainless neoprene sweep on the pull side and an intumescent shoe on the push side, up to 1-1/2 in undercut

Manufacturer: NGP

NGP GapGuard 9590 Fire Door Bottom Gap Solution Stainless Steel

$450.00

US Made Supply

Your Orders

Sign InOrder HistoryOrder Status

Copyright © 2026 US Made, LLC. All Rights Reserved.

All content is for informational purposes only and does not constitute professional, legal, or compliance advice. Verify all requirements with the applicable standards and authorities. Standard names, spec section numbers, and related marks are the property of their respective owners. We cite them to show where a product is usually specified, not as a certification.

Secure Payments

VisaMastercardAmerican ExpressDiscoverApple PayGoogle PayShop PayPayPal