US Made Supply

✓ Verified

"very high quality. easy to app..."

✓ Verified

"So far - love the product and ..."

✓ Verified

"Product and application as des..."

Roofing & Roofs
Flat or Low Slope

Fire Suppression System Standards

NFPA and UL requirements for automatic fire suppression systems


Overview

Fire suppression system standards ensure the proper design, installation, testing, and maintenance of automatic fire suppression equipment. These standards cover various system types from commercial kitchen suppression to building-wide sprinkler systems and specialized clean agent systems.

Code Compliance: Fire suppression systems must comply with International Fire Code (IFC), local fire codes, and NFPA standards. All equipment must be listed by nationally recognized testing laboratories (NRTL) such as UL, FM, or ETL. Regular inspection and maintenance per these standards is essential for system reliability and code compliance.

This comprehensive guide covers the major standards governing fire suppression systems, including NFPA 13 for sprinkler systems, UL 300 for kitchen systems, NFPA 96 for commercial cooking equipment, and NFPA 2001 for clean agent systems. Each standard provides specific requirements for design, installation, testing, and maintenance.

Commercial Kitchen Systems

Commercial cooking operations require specialized fire suppression systems designed for grease fires and high-temperature cooking equipment. These systems use wet chemical agents to suppress cooking oil fires and automatically shut down gas supplies.

Kitchen Systems

UL 300

Fire testing standard for pre-engineered kitchen suppression systems using wet chemical agents

View Guide

Kitchen Systems

NFPA 96

Ventilation control and fire protection requirements for commercial cooking operations

View Guide

Kitchen Systems

NFPA 17A

Design, installation, and maintenance of wet chemical extinguishing systems

View Guide

Key Requirements

  • Systems must protect cooking equipment, exhaust hoods, and ductwork
  • Wet chemical agents specifically formulated for cooking oil fires
  • Automatic gas and electrical shutoff upon system activation
  • Semi-annual inspection and maintenance required for most jurisdictions
  • UL 300 listing required for all kitchen suppression equipment

Building Sprinkler Systems

Automatic sprinkler systems provide building-wide fire protection through water-based suppression. These systems are required in most commercial buildings and must be designed according to occupancy hazard classification and local fire codes.

Sprinkler Systems

NFPA 13

Standard for the installation of sprinkler systems, covering design, materials, and system components

View Guide

System Types & Design

  • Wet Systems: Pipes filled with water under pressure (most common)
  • Dry Systems: Pipes filled with pressurized air/nitrogen (unheated areas)
  • Preaction Systems: Two-step activation for sensitive areas
  • Deluge Systems: Open sprinklers for high-hazard occupancies
  • Hydraulic calculations required for all design density areas

Clean Agent Systems

Clean agent fire suppression systems protect sensitive equipment and areas where water damage must be avoided. These systems use gaseous agents that leave no residue and are electrically non-conductive, making them ideal for data centers, telecommunications facilities, and museums.

Clean Agent Systems

NFPA 2001

Standard for clean agent fire extinguishing systems protecting sensitive equipment

View Guide

Agent Types & Applications

  • HFC Agents: FM-200, FE-25 for occupied spaces
  • FK Agents: Novec 1230 with zero ozone depletion potential
  • Inert Gas: Nitrogen, argon mixtures for total flooding
  • CO2 Systems: For unoccupied areas and special hazards
  • Room integrity testing required to ensure proper gas concentration retention

Standards & Implementation Guides

Our comprehensive implementation guides provide detailed information on each major standard governing fire suppression systems. These guides include installation requirements, testing procedures, maintenance schedules, and compliance strategies.

Kitchen Systems

UL 300

Fire testing standard for pre-engineered kitchen suppression systems using wet chemical agents

View Guide

Kitchen Systems

NFPA 96

Ventilation control and fire protection requirements for commercial cooking operations

View Guide

Kitchen Systems

NFPA 17A

Design, installation, and maintenance of wet chemical extinguishing systems

View Guide

Sprinkler Systems

NFPA 13

Standard for the installation of sprinkler systems, covering design, materials, and system components

View Guide

Clean Agent Systems

NFPA 2001

Standard for clean agent fire extinguishing systems protecting sensitive equipment

View Guide

Was this resource helpful?

Your feedback helps us improve our technical resources and guides.

Customer Support

Terms of ServicePrivacy PolicyShipping & DeliveryReturns & RefundsFAQs

Copyright © 2025 US Made, LLC. All Rights Reserved.