Standards for emergency lighting, exit signs, fire alarms, and egress systems


Overview

Emergency and life safety systems are critical components of building design that protect occupants during emergencies. These systems include emergency lighting, exit signs, fire detection and alarm systems, emergency power supplies, and means of egress components. Proper design, installation, and maintenance of these systems are mandated by building codes and life safety standards.

Code Compliance: Emergency and life safety systems must comply with the International Building Code (IBC), International Fire Code (IFC), NFPA 101 Life Safety Code, and local amendments. Equipment must be listed by nationally recognized testing laboratories (NRTL) such as UL, FM, or ETL.

This comprehensive guide covers the major standards governing emergency and life safety systems, including UL 924 for emergency lighting, NFPA 72 for fire alarms, NFPA 110 for emergency power, and IBC Chapter 10 for means of egress. Each standard provides specific requirements for design, installation, testing, and maintenance.

Emergency Lighting & Exit Signs

Emergency lighting systems provide illumination during power failures to facilitate safe evacuation. Exit signs mark egress routes and exits. Both are required by building codes in most commercial and institutional occupancies.

Emergency Lighting

UL 924

Emergency Lighting & Power Equipment standards for battery backup systems, exit signs, and emergency luminaires

View Guide

Exit Markings

Photoluminescent Systems

UL 1994 standards for glow-in-the-dark exit signs and egress path markings for high-rise buildings

View Guide

Key Requirements

  • 90-minute minimum emergency duration for battery backup systems
  • 1 footcandle average, 0.1 footcandle minimum illumination on egress paths
  • 10-second maximum transfer time from normal to emergency power
  • Monthly 30-second testing and annual 90-minute testing required

Fire Detection & Alarms

Fire detection and alarm systems provide early warning of fire conditions, automatically notify occupants and emergency responders, and may initiate other building systems such as smoke control or fire suppression.

Fire Alarms

NFPA 72

National Fire Alarm and Signaling Code covering fire detection, alarm systems, and emergency communication

View Guide

System Components

  • Fire alarm control panels (FACP) and notification appliance circuits
  • Smoke detectors, heat detectors, and manual pull stations
  • Horns, strobes, and voice evacuation systems
  • Carbon monoxide detection and emergency communication systems

Emergency Power Systems

Emergency power systems provide backup electrical power for life safety systems during utility power failures. These include generators, battery systems, inverters, and transfer switches that maintain power to critical systems.

Emergency Power

NFPA 110

Emergency and Standby Power Systems standard for generators, transfer switches, and emergency power supply systems

View Guide

System Classifications

  • Level 1: Critical life safety systems (fire pumps, emergency lighting)
  • Level 2: Less critical systems (HVAC, data processing)
  • Type 10: 10-second transfer time for emergency systems
  • Class 2: 2-hour minimum runtime capacity

Egress & Life Safety Systems

Means of egress systems provide safe evacuation routes from buildings during emergencies. These include exits, exit access routes, exit discharge paths, and all associated components such as doors, stairs, and corridors.

Building Codes

IBC Chapter 10

Means of Egress requirements including occupant loads, exit requirements, door specifications, and accessible egress

View Guide

Life Safety

NFPA 101

Life Safety Code covering occupancy requirements, construction features, protection systems, and means of egress

View Guide

Design Considerations

  • Occupant load calculations determine required exit capacity
  • Travel distance limitations based on occupancy and sprinkler protection
  • Accessible means of egress for persons with disabilities
  • Minimum corridor widths, door sizes, and stair dimensions

Standards & Implementation Guides

Our comprehensive implementation guides provide detailed information on each major standard governing emergency and life safety systems. These guides include installation requirements, testing procedures, maintenance schedules, and compliance strategies.

Emergency Lighting

UL 924

Emergency Lighting & Power Equipment standards for battery backup systems, exit signs, and emergency luminaires

View Guide

Exit Markings

Photoluminescent Systems

UL 1994 standards for glow-in-the-dark exit signs and egress path markings for high-rise buildings

View Guide

Fire Alarms

NFPA 72

National Fire Alarm and Signaling Code covering fire detection, alarm systems, and emergency communication

View Guide

Emergency Power

NFPA 110

Emergency and Standby Power Systems standard for generators, transfer switches, and emergency power supply systems

View Guide

Building Codes

IBC Chapter 10

Means of Egress requirements including occupant loads, exit requirements, door specifications, and accessible egress

View Guide

Life Safety

NFPA 101

Life Safety Code covering occupancy requirements, construction features, protection systems, and means of egress

View Guide

Was this resource helpful?

Your feedback helps us improve our technical resources and guides.

Customer Support

Terms of ServicePrivacy PolicyShipping & DeliveryReturns & RefundsFAQs

Copyright © 2025 US Made, LLC. All Rights Reserved.