FLDA angled floor door, open, showing the gas spring, hinges and hold-open arm under the diamond plate cover, on a coated anchoring flange
FLDE floor door for an existing opening, open, showing the stiffeners, gas spring and hinges under the diamond plate cover
FLDD drainable floor door, open, showing the gutter channel inside the frame and the hold-open arm
FLDR recessed floor door, open, showing the smooth plate cover with stiffeners and its hold-open arm
FHD fire-rated floor door shown open, with gas springs and fire caution labels under the cover, and closed, with its aluminum tread plate

Floor Access Doors

JL Industries

Authorized Distributor

Priced per project

Not stocked. Lead time comes with your quote.

Series

US Made Products

Business Support

American businesses trust US Made Supply because we do the research.

Call 714-248-6555 or email us.

Pick the closest series, then send the size and load or your plans. We reply with pricing, lead time and the submittal.

None of these doors are stocked, and the manufacturer quotes each one per project for its size and options. Send the series with the size and load. Plans work too.

Compare series

PhotoSeriesUseLive loadSizesCoverFire ratingInstall
FLDA Angled
FLDA AngledSelected

New concrete slab, indoors and dry

Indoor foot traffic where rainwater is not a concern

300 lb/sq ft pedestrian live load

24 × 24 to 60 × 60 in, single or double leaf, custom sizes

1/4 in diamond aluminum plate

Not fire-rated

Cast into new concrete

FLDE Existing opening
FLDE Existing opening

The opening is already cut

Retrofit into an opening already in the floor

300 lb/sq ft pedestrian live load

Frame 23 × 23 to 47 × 47 in for existing openings 24 × 24 to 48 × 48 in, custom sizes

1/4 in diamond aluminum plate

Not fire-rated

Bolted into an existing opening at least 3 in deep, hardware by others

FLDD Drainable
FLDD Drainable

Water can reach the door and has to drain away

A gutter in the frame drains moisture away from the opening

300 lb/sq ft pedestrian live load

24 × 24 to 60 × 60 in, single or double leaf, custom sizes

1/4 in diamond aluminum plate

Not fire-rated

Cast into new concrete, drain pipe by others

FLDR Recessed
FLDR Recessed

Tile or carpet should run across the door

The cover takes 1/8 in tile or carpet so the floor finish carries across

150 lb/sq ft pedestrian live load

24 × 24 to 48 × 48 in, custom sizes

1/4 in smooth aluminum plate with a lip for 1/8 in flooring, 3/16 in lip optional

Not fire-rated

Cast into new concrete

FHD Fire-rated
FHD Fire-rated

The floor-ceiling assembly is fire-rated

Fire-rated floor-ceiling assemblies in dry locations

150 lb/sq ft live load

26 × 24 to 64 × 60 in at 1 or 2 hours, up to 42 × 60 or 48 × 48 in at 3 hours

1/4 in aluminum tread plate on a 14 gauge galvanneal liner with ceramic fiber insulation

1, 2 or 3 hours, QAI listed (certificate F482-1) to NFPA 288 and CAN/ULC S101

Cast in or retrofit in concrete, or wood framing at 1 or 2 hours

FLDA Angled
FLDA AngledSelected

New concrete slab, indoors and dry

Use

Indoor foot traffic where rainwater is not a concern

Live load

300 lb/sq ft pedestrian live load

Sizes

24 × 24 to 60 × 60 in, single or double leaf, custom sizes

Cover

1/4 in diamond aluminum plate

Fire rating

Not fire-rated

Install

Cast into new concrete

FLDE Existing opening
FLDE Existing opening

The opening is already cut

Use

Retrofit into an opening already in the floor

Live load

300 lb/sq ft pedestrian live load

Sizes

Frame 23 × 23 to 47 × 47 in for existing openings 24 × 24 to 48 × 48 in, custom sizes

Cover

1/4 in diamond aluminum plate

Fire rating

Not fire-rated

Install

Bolted into an existing opening at least 3 in deep, hardware by others

FLDD Drainable
FLDD Drainable

Water can reach the door and has to drain away

Use

A gutter in the frame drains moisture away from the opening

Live load

300 lb/sq ft pedestrian live load

Sizes

24 × 24 to 60 × 60 in, single or double leaf, custom sizes

Cover

1/4 in diamond aluminum plate

Fire rating

Not fire-rated

Install

Cast into new concrete, drain pipe by others

FLDR Recessed
FLDR Recessed

Tile or carpet should run across the door

Use

The cover takes 1/8 in tile or carpet so the floor finish carries across

Live load

150 lb/sq ft pedestrian live load

Sizes

24 × 24 to 48 × 48 in, custom sizes

Cover

1/4 in smooth aluminum plate with a lip for 1/8 in flooring, 3/16 in lip optional

Fire rating

Not fire-rated

Install

Cast into new concrete

FHD Fire-rated
FHD Fire-rated

The floor-ceiling assembly is fire-rated

Use

Fire-rated floor-ceiling assemblies in dry locations

Live load

150 lb/sq ft live load

Sizes

26 × 24 to 64 × 60 in at 1 or 2 hours, up to 42 × 60 or 48 × 48 in at 3 hours

Cover

1/4 in aluminum tread plate on a 14 gauge galvanneal liner with ceramic fiber insulation

Fire rating

1, 2 or 3 hours, QAI listed (certificate F482-1) to NFPA 288 and CAN/ULC S101

Install

Cast in or retrofit in concrete, or wood framing at 1 or 2 hours

Comparison of 5 series in this range by use, live load, sizes, cover, fire rating, install.

Related Documents & Downloads

Floor door catalog (PDF)FLDA submittal (PDF)FLDE submittal (PDF)FLDD submittal (PDF)FLDR submittal (PDF)FHD submittal, 1 hour (PDF)FHD submittal, 2 hour (PDF)FHD submittal, 3 hour (PDF)Guide specification, floor doors (DOCX)Guide specification, fire-rated floor doors (DOCX)Cross-reference to other brands (PDF)Warranty (PDF)

Frequently Asked Questions

Can you match the floor door I'm replacing?

Usually. The manufacturer publishes a cross-reference from these series to Acudor, Babcock-Davis, Bilco, Karp, Nystrom and USF Fabrication floor doors. Send the old model number or a photo of its label and we confirm the match and the size before we quote.

Which series are fire-rated?

Only FHD. It is listed for 1, 2 or 3 hours to NFPA 288 and CAN/ULC S101. A 165°F fusible link closes it in a fire, except at 48 × 48 and 64 × 60 in, where the closer is not offered. It is for dry locations only. The other four series are not fire-rated.

What load do they carry?

FLDA, FLDE and FLDD are rated for a 300 lb/sq ft pedestrian live load. FLDR and FHD are rated for 150 lb/sq ft. If the door has to carry more than foot traffic, put the load on the quote form and we check it with the manufacturer.

What size do I send?

These doors are ordered by the inside dimension of the frame. Send the opening size and we confirm the order size. For a door going into an existing opening, the opening is 1 in larger than the frame.

How long does it take?

None of these doors are stocked, so the lead time depends on the order. It comes back with your quote.

Is it made in the USA?

Yes. The manufacturer lists all five series as built in Bloomington, Minnesota or Commerce, California.

What is the warranty?

The manufacturer warrants its floor door products for five years against defects in materials and workmanship.

How do I send plans?

Tick "I have plans or specs to share" on the quote form. We email you, and you reply with the drawings.

US Made Supply

Your Orders

Sign InOrder HistoryOrder Status

Copyright © 2026 US Made, LLC. All Rights Reserved.

All content is for informational purposes only and does not constitute professional, legal, or compliance advice. Verify all requirements with the applicable standards and authorities. Standard names, spec section numbers, and related marks are the property of their respective owners. We cite them to show where a product is usually specified, not as a certification.

Secure Payments

VisaMastercardAmerican ExpressDiscoverApple PayGoogle PayShop PayPayPal